Description
Industrial RS-422/485 repeater with 3KV isolation
The ISC-1212-I is a RS-422/485 repeater which boosts the RS-422/485 signals to extend the reach distance up to 4000 ft (1200m) and increase the maximum number of connection up to 128 nodes. With a special circuitry, ISC-1212-I is able to automatically detect the data flow and switch the direction of the data lines accordingly. “Auto baud rate detector” enables ISC-1212-I to automatically configure RS-422/485 signals to any baud rate without external switch setting. Build in opto-isolations on ISC-1212-I provides 3000VDC of isolation to protect the host computer from destructive voltage spikes on the RS- 422/485 data lines. ISC-1212-I also offers internal surge-protection on the data lines. The internal high-speed transient suppressors on each data line protect the module from dangerous voltages levels or spikes. Therefore, the ISC-1212-I is a reliable RS-422/485 repeater and can satisfy most demand of operating environment.
• Automatic internal RS-422/485 bus supervision
• No external flow control signals required for RS-485
• Serial type support auto detect and switch
• Supported baud rate up to 115.2Kbps
• Reach distance up to 4000 feet (1200m)
• Support multiple baud rate and multiple data format
• Reserved space for termination resistors (R8,R9)
• Power and data flow indicator for troubleshooting
• Power requirement : +9 ~ 30VDC
• DIN-Rail and wall mounting enabled
Specification
- Physical Ports
- RS-422/485 Connector
- 10-pin terminal block
- RS-422/485 Signals
- RS-422 : TX+, TX-, RX+
- RX-RS-485 : Data+, Data-
- Baud Rate
- 300 ~ 115.2 Kbps
- Data bit
- 5, 6, 7, 8
- Stop bit
- 1, 1.5, 2
- Parity
- None, Even, Odd, Space, Mark
- Flow Control
- XON/XOFF(software)
- Auto Hardware Direction Control for RS-485
- LED Indicators
- Power Indicator
- Green : Power LED x 1
- TxD Indicator
- Green LED x 1
- RxD Indicator
- Red LED x 1
- Power
- Input Power
- +9 ~ 30 VDC power inputs on 10-pin terminal block
- Power Consumption (Typ.)
- 0.7 Watts.
- Physical Characteristics
- Enclosure
- IP-30
- Dimensions (W x D x H)
- 71.2(W) x 25.3(D) x 100.6(H) mm (2.8x1x3.96 inch.)
- Weight (g)
- 130g
- Environmental
- Storage Temperature
- -25 to 85°C (-13 to 185°F)
- Operating Temperature
- -10 to 70°C (14 to 158°F)
- Operating Humidity
- 5% to 95% Non-condensin
- Regulatory Approvals
- EMI
- FCC Part 15, CISPR (EN55022) class A,
- EMS
- EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
- Shock
- IEC60068-2-27
- Free Fall
- IEC60068-2-32
- Vibration
- IEC60068-2-6
- Warranty
- 2 years
Filter criteria
- Isolation
- yes
- Manufacturer
- ORING
- Status
- Phased out
- Customs Tariff Number
- 84733020
- WEEE Number
- DE76344510