Beschreibung
The I-2533CS is a local CAN bridge used to establish a connection between two CAN bus systems via single mode fiber optic. It can unleash the transmission distance limitation of the fiber optic due to the higher CAN baud rate. That is to say that the total network distance can be extended. When applying the I-2533CS in the two CAN sub-network, the bus error on one CAN network don’t affect the operation of another CAN network, and the two CAN network can communicate with each other by using different CAN baud rate for highly flexibility. These features help users’ applications more powerful and flexible.
● Fiber Type: SC type ; Single mode ; 100 Base-FX
● Maximum transmission distance up to 30 km (60km for I-2533CS-60) at any CAN baud rate
● TJA1042T CAN transceiver
● 2500 Vrms isolation on the CAN side
● Support both CAN 2.0A and CAN 2.0B specification
● Fully compatible with the ISO 11898-2 standard
● Built-in switch for 120 Ω terminator resistor
● Removable terminal block
● Mount easily on DIN-Rail
● Rotary switch for CAN baud rate configuration
● Allow user-defined baud rate
● Fiber broken line detection
● Utility tool for message filter configuration
Spezifikation
- CAN Interface
- Connector
- Screwed terminal block (CAN_GND, CAN_L, CAN_H)
- Baud Rate (bps)
- 10 k ~ 1 M
- Transmission Distance (m)
- Depend on baud rate
- Terminator Resistor
- Switch for 120Ω terminator resistor
- Isolation
- 2500 Vrms on the CAN side
- Specification
- ISO 11898-2, CAN 2.0A and CAN 2.0B
- Propagation Delay
- 190us
- Fiber Interface
- Type
- SC Duplex type ; Single mode ; 100 Base-FX
- Wave Length (nm)
- 1310
- Fiber Cable (μm)
- 8.3/125, 8.7/125, 9/125 or 10/125
- Transmission Distance (km)
- 30 (indicative only)
- Min. TX Output (dBm)
- -15
- Max. TX Output (dBm)
- -8
- Max. RX Sensitivity (dBm)
- -34
- Max. RX Overload (dBm)
- -5
- Budget (dBm)
- 19
- UART Interface
- COM1
- RS-232 (configuration only)
- COM1 Connector
- Screwed terminal block (RXD, TXD, GND)
- LED
- Round LED
- PWR, FB_Ack, FB_Err, CAN_Err, CAN_Tx and CAN_Rx LEDs
- Power
- Power supply
- Unregulated +10 ~ +30 VDC
- Protection
- Power reverse polarity protection, Over-voltage brown-out protection
- Power Consumption
- 0.125 @ 24VDC
- Mechanism
- Installation
- DIN-Rail
- Dimensions
- 33.0 mm x 126 mm x 101 mm (W x L x H)
- Environment
- Operating Temp.
- -25 ~ 75 ℃
- Storage Temp.
- -30 ~ 80 ℃
- Humidity
- 10 ~ 90% RH, non-condensing
Filterkriterien
- Ethernet
- Fast
- Ports gesamt
- 01
- Ports RJ45
- 00
- Ports SFP
- 00
- Ports Fiber
- 01
- Host-Schnittstelle
- CAN
- Target-Schnittstelle
- Fiber
- Eingabe Protokoll
- CAN
- Hersteller
- ICPDAS
- Status
- Standard
- Zollnummer
- 85176200
- WEEE Nummer
- DE76344510